Ventilation and Duct Design

Ductwork connected to fume hoods may be arranged in a variety of patterns depending on requirements. Generally, the best exhaust system involves the shortest duct length and the fewest elbows. Duct size, length, and number of elbows affect static pressure loss and blower efficiency. Ideally, each fume hood should have its own ducting and blower to maximize hood flexibility and reduce danger of backdraft from other hoods.

Common or manifold ductwork designs can be used, provided duct and blower have been sized properly. In these designs, individual hood dampers are recommended to balance the system. Hood users must be aware of how different hood exhaust fumes will react when mixed in the ductwork. Rigid PVC ductwork is recognized as an excellent fume hood exhaust duct material. The smooth interior surface reduces static pressure loss and chemical waste build up, and PVC is extremely resistant to a wide variety of reagents. For some applications flexible PVC lined duct provides adequate service and can significantly reduce installation costs. When planning exhaust ducting, duct size, length, number of bends, and exhaust material must be considered.

Consult HEMCO for Lab Ventilation Solutions

InLine HEPA / Carbon Filter Pak

Filter paks are used in laboratory exhaust and supply systems to remove hazardous fumes & particulate from the airstream. Filters are loaded with virgin coconut activated carbon to efficiently absorb organic solvents and acid fumes. The filter pak housing features a hinged access door with gaskets and spring latches for convenient filter changes. Inlet and outlet plenums with duct connection collars are installed. The carbon filter pak can also be paired with a HEPA filter pak to collect particulate contaminants

Air Flow Monitor

Note: OSHA recommends Air flow monitors to be installed on all fume hoods.

Continuously monitors face velocity air flow of fume hood. Select and calibrate at desired fpm velocity set point. If the hood face velocity falls below set point, an audible alarm sounds and a visual red indicator light appears. Air flow alarm is factory installed or can be field installed. 115V/60Hz AC.

Cat. No. 51403

Air Flow Monitor with Digital Display

Continuously monitors face velocity air flow of fume hood. Select and calibrate at desired fpm velocity set point. If the hood face velocity falls below set point, an audible alarm sounds and a visual red indicator light appears. Air flow alarm is factory installed or can be field installed. 115V/60Hz AC.

Cat. No. 51406

InLine HEPA / Carbon Filter Pak

Filter paks are used in laboratory exhaust and supply systems to remove hazardous fumes & particulate from the airstream. Filters are loaded with virgin coconut activated carbon to efficiently absorb organic solvents and acid fumes. The filter pak housing features a hinged access door with gaskets and spring latches for convenient filter changes. Inlet and outlet plenums with duct connection collars are installed. The carbon filter pak can also be paired with a HEPA filter pak to collect particulate contaminants

Air Flow Monitor

Note: OSHA recommends Air flow monitors to be installed on all fume hoods.

 

Continuously monitors face velocity air flow of fume hood. Select and calibrate at desired fpm velocity set point. If the hood face velocity falls below set point, an audible alarm sounds and a visual red indicator light appears. Air flow alarm is factory installed or can be field installed. 115V/60Hz AC.

Cat. No. 51403

Air Flow Monitor with Digital Display

Continuously monitors face velocity air flow of fume hood. Select and calibrate at desired fpm velocity set point. If the hood face velocity falls below set point, an audible alarm sounds and a visual red indicator light appears. Air flow alarm is factory installed or can be field installed. 115V/60Hz AC.

Cat. No. 51406

Fume Hood Ductwork & Venting Accessories

Ducting and accessories are chemical resistant and easy to install.